Incubador Refrigerado con agitación orbital de gran volumen “S2102”

High volume orbital shaker incubators “S2102”

FAN AIR CIRCULATED, WITH OR WITHOUT REFRIGERATION
DIGITAL ELECTRONIC CONTROL OF SPEED, TEMPERATURE AND TIME. FOR LONG OPERATING PERIODS.

SAFETY

TRIPLE PROTECTION MOTOR DRIVE: OVER TEMPERATURE, IRREGULAR MOVEMENTS, AUTOMATIC STOP WHEN THE DOOR IS OPENED, TEMPERATURE ALARM, THERMAL CUTOUT.

GENERAL FEATURES

Metallic external case epoxy-coated.
Current and set digital reading of temperature, time and speed parameters. Acoustic alarm and illuminated indicator at the end of the cycle and also to indicate temperature and / or time programs errors.
Automatic switch off mechanism when the shaker door is opened.
Motor over load protection, with automatic switch off activation.
Induction drive motor, where the drive mechanism has an anti vibration system. Refrigerated models have a hermetically sealed compressor unit with a ventilated condenser.
Internal case made of stainless steel AISI 316 with polished finish and glazed door for a handy visibility of the samples process.
Internal platform with multi-adapter positions for differing accessories, such as: conical flask adapters, microtitre plate holders and universal tray with adjustable tension springs for other non standard sized vessels. 
MODELS FRAMEWORK TYPE  “S2102”
Made with two doors framework type and double glass windows which allow visibi- lity of the material exposed in the inside
Two removable upper trays for high volume Erlenmeyer flasks accommodation in the lower tray.
Adjustable outlet hole for the air in the inside of the chamber. Amplitude of oscilation: 25mm.
With wheels for movements and adjustable support for a stabled fixing.

CONTROL PANEL

00. LCD Display
01. Heater "ON" indicator.
02. Alarm indicator.
03. Refrigeration compressor "ON" indicator. (only refrigerated models)
04. Time function push button. 
05. Modify and confirm push button. 
06. Start / Stop push button. 
07. Adjust temperature push button (only refrigerated models). 
08. Speed push button. 
09. Rotation push button. 
10. Reduce value push button. 
11. Increase value push button. 
CódigoRotation amplitude mmRegulación velocidad r.p.m.Precision controlRefrigerated, temp.°CHeatingControl range °CAccuracy TemperatureStability ° CTimerUsable platform mmPlatformFlask capacity mlMeasurement mmWeight KgConsumption w
5312130Continuous adjustment from 0 to 50 mm orbital from 30 to 400 rpm. 1 rpm. NO YESfrom ambient +5 °C to 60°C 0,1ºC ±1°Cfrom 0 to 500 hours 370 x 400 mm. 1 6 x 1000ml. ó 9 x 500ml. or 12 x 250ml. or 16 x 100ml. or 20 x 50ml. 610x610x510 mm. 72 Kg. 490 W.
5312131Continuous adjustment from 0 to 50 mm orbital from 30 to 400 rpm. 1 rpm. SI SIfrom ambient +5 °C to 60°C 0,1ºC ±1°Cfrom 0 to 500 hours 420 x 380 mm. 1 9 x 1000ml. or 9 x 500ml. or 16 x 250ml. or 20 x 100ml. or 25 x 50ml.700x740x560 mm. 100 Kg. 580 W.
5312132 25 mm.from 40 to 300 r.p.m. 1 rpm. NO YESfrom ambient +5 °C to 60°C 0,1ºC ±1-2°Cfrom 0 to 500 hours 734 x 458 mm. 2 4 x 5000ml or 8 x 3000ml. or 8 x 2000ml. or 24 x 1000ml. óor44 x 500ml. or 56 x 250ml. or 104 x 100ml. or 104 x 50ml. 1440x950x700 mm. 200 Kg. 930 W.